-
Description
A well-performing range of inverters from 275VA to 2400VA for small to medium sized systems, with an optional built-in PWM solar charge controller. The devices in this series offer low self-consumption, a battery protection algorithm, and compact construction.
Plug and forget
The inverters of the AJ series have been present in the market for many years and have widely demonstrated their superior reliability. Being delivered with AC and DC cables, they are truly "plug and forget" devices.Self-consumption
In addition to a high surge power capacity, the AJ have a very low self-consumption thanks to a precise and efficient stand-by function. The load detection in stand-by is automatic and adjustable from very small loads.Battery protection
The inverters offer a battery protection function that intelligently manages the low voltage disconnect level as a function of how the battery is being used. The so-called B.L.O (Battery Lifetime Optimizer) protects the battery from repeated deep discharges, thus significantly prolonging the useful life of the battery.Specification
Product No. I1101 Inverter: Nominal battery voltage 12Vdc Input voltage range 10.5 – 16Vdc (24Vdc max.) Continuous power @ 25°C 200VA Power 30 min. @ 25°C 275VA Power 5 min. @ 25°C 350VA Power 5 sec. @ 25°C 450VA Maximum asymmetric load 150VA Max. efficiency (%) 93 % Cos φ max. 0.1 – 1 up to 200 VA Detection of the load 2W (only with the solar option -S) Current of short-circuit 2 sec. (exit) 2.3A (4.6A*) Output voltage Sine wave 230Vac (120Vac*) ±5% Frequency 50Hz (60Hz*) ± 0.05% (crystal controlled) Distortion THD (resistive load) < 5% (@ Pnom.) Consumption Stand-by 0.3W** Consumption « ON » no load 2.4W Overheat protection (±5°C) Shut down @ 75°C - Auto-restart @ 70°C Overload and short circuit protection Automatic disconnection with 2 time restart attempt Reverse polarity protection by internal fuse 60A Deep discharge battery protection Shut off @ 0.87 x Unom - Automatic restart @ Unom Max. battery voltage Shut off @ >1.33 x Unom - Automatic restart @ < Umax Acoustic alarm Before low battery or overheating disconnection General data: Weight 2.4 kg Dimensions hxwxl [mm] 142x163x84 Protection index IP IP 30 conforms to DIN 40050 Certification ECE-R 10 (E24) ✓ EC conformity EN 61000-6-1, EN 61000-6-3, EN 55014, EN 55022, EN 60950-1 Operating temperature -20°C up to +50°C Relative humidity in operation 95% without condensation Ventilation forced From 45°C ± 5°C Acoustic level < 45 dB (with ventilation) Warranty 5 years Approximate correction of Pnom -1.5%/°C since +25°C Recommended battery capacity > 5 x Pnom/Unom (recommended value in Ah) Length cables (Battery/left AC) 1.2m / 1m Options AJ 275-12-S Solar regulator: Voltage max. 25Vdc Current max. 10Adc Principle Floating 3 stages (I/U/UO) Absorption voltage 14.4Vdc Floating voltage 13.6Vdc Plug for remote control (RCM) ✓ * 120Vac/60Hz on request
** Standby with solar option -S -
Product image
Download