Description
A well-performing range of inverters from 275VA to 2400VA for small to medium sized systems, with an optional built-in PWM solar charge controller. The devices in this series offer low self-consumption, a battery protection algorithm, and compact construction.
Plug and forget
The inverters of the AJ series have been present in the market for many years and have widely demonstrated their superior reliability. Being delivered with AC and DC cables, they are truly "plug and forget" devices.Self-consumption
In addition to a high surge power capacity, the AJ have a very low self-consumption thanks to a precise and efficient stand-by function. The load detection in stand-by is automatic and adjustable from very small loads.Battery protection
The inverters offer a battery protection function that intelligently manages the low voltage disconnect level as a function of how the battery is being used. The so-called B.L.O (Battery Lifetime Optimizer) protects the battery from repeated deep discharges, thus significantly prolonging the useful life of the battery.Specification
Product No. I1110 Inverter: Nominal battery voltage 24Vdc Input voltage range 21–32Vdc (40Vdc max.) Continuous power @ 25°C 2000VA Power 30 min. @ 25°C 2400VA Power 5 min. @ 25°C 2800VA Power 5 sec. @ 25°C 5200VA Maximum asymmetric load 1200VA Max. efficiency (%) 94% @ 300VA Cos φ max. 0.1 – 1 up to 2000VA Detection of the load Adjustable : 1 g 20W Current of short-circuit 2 sec. (exit) 30Aac (60Aac*) Output voltage Sine wave 230Vac (120Vac*) ±5% Frequency 50 Hz (60Hz*) ± 0.05% (crystal controlled) Distortion THD (resistive load) < 3% (@ Pnom & Uin nom.) Consumption Stand-by 1.2W Consumption « ON » no load 16W Overheat protection (±5°C) Shut down @ 75°C - Auto-restart @ 70°C Short circuit protection Automatic disconnection with 2 time restart attempt Reverse polarity protection Protected by internal fuse 150A Deep discharge battery protection Shut off @ 0.87 x Unom - Automatic restart @ Unom Max. battery voltage Shut off @ >1.33 x Unom - Automatic restart @ < Umax Acoustic alarm Before low battery or overheating disconnection General data: Weight 18 kg Dimensions hxwxl [mm] 273x399x117 Protection index IP IP 20 conforms to DIN 40050 Certification ECE-R 10 (E24) ✓ EC conformity EN 61000-6-1, EN 61000-6-3, EN 55014, EN 55022, EN 60950-1 Operating temperature -20°C up to +50°C Relative humidity in operation 95% without condensation Ventilation forced From 45°C ± 5°C Acoustic level < 45 dB (with ventilation) Warranty 5 years Approximate correction of Pnom -1.5%/°C since +25°C Recommended battery capacity > 5 x Pnom/Unom (recommended value in Ah) Length cables (Battery/left AC) 1.7m / 1m Options AJ 2400-24-S Solar regulator: Voltage max. 45Vdc Current max. 30A Principle Floating 3 stages (I/U/UO) Absorption voltage 28.8Vdc Floating voltage 27.2Vdc Remote control JT8 supplied with 5 m cable ✓ * 120Vac/60Hz on request
** Standby with solar option -S -
Product image
Download