Beschreibung
A well-performing range of inverters from 275VA to 2400VA for small to medium sized systems, with an optional built-in PWM solar charge controller. The devices in this series offer low self-consumption, a battery protection algorithm, and compact construction.
Plug and forget
The inverters of the AJ series have been present in the market for many years and have widely demonstrated their superior reliability. Being delivered with AC and DC cables, they are truly "plug and forget" devices.Self-consumption
In addition to a high surge power capacity, the AJ have a very low self-consumption thanks to a precise and efficient stand-by function. The load detection in stand-by is automatic and adjustable from very small loads.Battery protection
The inverters offer a battery protection function that intelligently manages the low voltage disconnect level as a function of how the battery is being used. The so-called B.L.O (Battery Lifetime Optimizer) protects the battery from repeated deep discharges, thus significantly prolonging the useful life of the battery.Technische Daten
Product No. I1106 Inverter: Nominal battery voltage 48Vdc Input voltage range 42 –64Vdc (64Vdc max.) Continuous power @ 25°C 500VA Power 30 min. @ 25°C 700VA Power 5 min. @ 25°C 900VA Power 5 sec. @ 25°C 1400VA Maximum asymmetric load 300VA Max. efficiency (%) 94 Cos φ max. 0.1 – 1 up to 500VA Detection of the load Adjustable : 1 g 20W Current of short-circuit 2 sec. (exit) 7A (14A*) Output voltage Sine wave 230Vac (120Vac*) ±5% Frequency 50Hz (60Hz*) ± 0.05% (crystal controlled) Distortion THD (resistive load) < 5% (@ Pnom.) Consumption Stand-by 1.5W Consumption « ON » no load 12W Overheat protection (±5°C) Shut down @ 75°C - Auto-restart @ 70°C Overload and short circuit protection Automatic disconnection with 2 time restart attempt Reverse polarity protection per internal fuse 60A Deep discharge battery protection Shut off @ 0.87 x Unom - Automatic restart @ Unom Max. battery voltage Shut off @ >1.33 x Unom - Automatic restart @ < Umax Acoustic alarm Before low battery or overheating disconnection General data: Weight 4.5 kg Dimensions hxwxl [mm] 142x240x84 Protection index IP IP 30 conforms to DIN 40050 Certification ECE-R 10 (E24) Not available EC conformity EN 61000-6-1, EN 61000-6-3, EN 55014, EN 55022, EN 60950-1 Operating temperature -20°C up to +50°C Relative humidity in operation 95% without condensation Ventilation forced From 45°C ± 5°C Acoustic level < 45 dB (with ventilation) Warranty 5 years Approximate correction of Pnom -1.5%/°C since +25°C Recommended battery capacity > 5 x Pnom/Unom (recommended value in Ah) Length cables (Battery/left AC) 1.5m / 1m Options AJ 600-24-S Solar regulator: Voltage max. 90Vdc Current max. 15Adc Principle Floating 3 stages (I/U/UO) Absorption voltage 57.6Vdc Floating voltage 54.4Vdc Plug for remote control (RCM) ✓ * 120Vac/60Hz on request
** Standby with solar option -S -
Produktbild
Downloads