Descripción
A well-performing range of inverters from 275VA to 2400VA for small to medium sized systems, with an optional built-in PWM solar charge controller. The devices in this series offer low self-consumption, a battery protection algorithm, and compact construction.
Plug and forget
The inverters of the AJ series have been present in the market for many years and have widely demonstrated their superior reliability. Being delivered with AC and DC cables, they are truly "plug and forget" devices.Self-consumption
In addition to a high surge power capacity, the AJ have a very low self-consumption thanks to a precise and efficient stand-by function. The load detection in stand-by is automatic and adjustable from very small loads.Battery protection
The inverters offer a battery protection function that intelligently manages the low voltage disconnect level as a function of how the battery is being used. The so-called B.L.O (Battery Lifetime Optimizer) protects the battery from repeated deep discharges, thus significantly prolonging the useful life of the battery.Especificaciones técnicas
Product No. I1108 Inverter: Nominal battery voltage 24Vdc Input voltage range 21–32Vdc (44Vdc max.) Continuous power @ 25°C 1000VA Power 30 min. @ 25°C 1300VA Power 5 min. @ 25°C 2000VA Power 5 sec. @ 25°C 2800VA Maximum asymmetric load 600VA Max. efficiency (%) 94 Cos φ max. 0.1 – 1 up to1000VA Detection of the load Adjustable : 1 g 20W Current of short-circuit 2 sec. (exit) 13Aac (26Aac*) Output voltage Sine wave 230Vac (120Vac*) ±5% Frequency 50 Hz (60Hz*) ± 0.05% (crystal controlled) Distortion THD (resistive load) < 5% (@ Pnom. & Uin nom.) Consumption Stand-by 1.2W Consumption « ON » no load 13W Overheat protection (±5°C) Shut down @ 75°C - Auto-restart @ 70°C Short circuit protection Automatic disconnection with 2 time restart attempt Reverse polarity protection Protected by internal fuse 100A Deep discharge battery protection Shut off @ 0.87 x Unom - Automatic restart @ Unom Max. battery voltage Shut off @ >1.33 x Unom - Automatic restart @ < Umax Acoustic alarm Before low battery or overheating disconnection General data: Weight 8.5 kg Dimensions hxwxl [mm] 142x428x84 Protection index IP IP 30 conforms to DIN 40050 Certification ECE-R 10 (E24) ✓ EC conformity EN 61000-6-1, EN 61000-6-3, EN 55014, EN 55022, EN 60950-1 Operating temperature -20°C up to +50°C Relative humidity in operation 95% without condensation Ventilation forced From 45°C ± 5°C Acoustic level < 45 dB (with ventilation) Warranty 5 years Approximate correction of Pnom -1.5%/°C since +25°C Recommended battery capacity > 5 x Pnom/Unom (recommended value in Ah) Length cables (Battery/left AC) 1.5m / 1m Options AJ 1300-24-S Solar regulator: Voltage max. 45Vdc Current max. 25A Principle Floating 3 stages (I/U/UO) Absorption voltage 28.8Vdc Floating voltage 27.2Vdc Remote control JT8 supplied with 5 m cable ✓ * 120Vac/60Hz on request
** Standby with solar option -S -
Imagen del producto
Descarga